Installation - Desa GA3700 Owner's Operation And Installation Manual

Unvented (vent-free) gas fireplace
Table of Contents

Advertisement

AIR FOR COMbUSTION AND VENTILATION
ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
and one within 12" of the floor. Connect these
items directly to the outdoors or spaces open
to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation for required size
of ventilation grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system's circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install fire-
place. Follow all local codes.
WARNING: Make sure the
selector switch is in the OFF po-
sition before installing heater
8
Continued
Outlet
Air
Inlet
Air
Figure 4 - Ventilation Air from Outdoors

INSTALLATION

fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing or other flammable
objects are less than 36" from
the front and 42" from top of
fireplace; for side clearances
see Figure 8, page 10
• in high traffic areas
• in windy or drafty areas
ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating
heater where impurities (such
as, but not limited, to tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may discolor
walls or cause odors.
www.desatech.com
Ventilated
Outlet
Attic
Air
Inlet Air
WARNING: Never install the
CAUTION: This fireplace cre-
To Attic
To
Crawl
Space
Ventilated
Crawl Space
113109-01G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga3555Ga3700tHrc100Hrc200Vygf33prcVygf33nrc

Table of Contents