Loading Page Malfunction; Web Ui Default Page May Change; Terminal Services Returns A Vbscript Error - Compaq 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server Release Note

Nas executor e7000 v2 - release notes
Hide thumbs Also See for 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server:
Table of Contents

Advertisement

The cluster group moves and the browser page needs to be
refreshed. The page can be refreshed by clicking the WebUI
Status screen and then returning to the Resource Groups screen.

Loading page malfunction

When using the Web UI, the page must load completely to
function properly.
When using the NAS Executor E7000 Web UI, wait for the
entire page to load. If an object on the UI is clicked, there may
be an error on the page, as the Javascript for the page had not
totally initialized.

Web UI default page may change

Re-running either Cluster Setup Tool or Rapid Startup changes
the default page.
If you re-run either the Cluster Setup Tool or Rapid Startup, the
default page is changed to something other than the status page.
To make the status page the default again, simply press the
Cancel button on the page.

Terminal Services returns a VBScript error

Terminal Services through the Web UI may cause a VBScript
error if the client has a trust violation with the NAS Server. This
is caused by the Internet Explorer settings. If you use an IP
address instead of name resolution through a DNS Server, there
will be a broken trust issue between the NAS server and the
browser. Internet Explorer does not accept ActiveX controls
from distrusted web sites.
1. On the client machine, open Internet Explorer 5.5 or higher.
2. From the menu, choose Tools->Internet Options.
StorageWorks by Compaq NAS Exectutor E7000 Release Notes
Release Notes
25

Advertisement

Table of Contents
loading

Table of Contents