Hub And Loop Switch Restrictions - Compaq 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server Release Note

Nas executor e7000 v2 - release notes
Hide thumbs Also See for 230039-001 - StorageWorks NAS Executor E7000 Model 904 Server:
Table of Contents

Advertisement

13. Navigate to the following drive:
Hkey_Local_Machine\Software\Compaq\StorageWorks
NAS.
14. Set the PRSState to –1.
15. Reboot.
After all software is uninstalled and the system is rebooted, re-
run the SAN Connect process, as outlined below and detailed in
the release notes section titled SAN Connection:
1. Verify that the SAN is not connected to the fiber HBAs in
the NAS device.
2. Connect to the NAS device's WEB interface
(http://NASname:3201).
3. Select the SAN Connect item from the left menu.
4. Answer questions about the specifics of the SAN.
5. Monitor the automated process that installs correct software
and reboots.
6. Physically connect the fiber cables to the NAS device when
prompted.

Hub and loop switch restrictions

Fibre channel hubs and loop switches are supported for use with
the StorageWorks NAS Executor E7000. However, there are two
restrictions that an administrator should be aware of.
1. LUNs that were created using the ACS 8.5 firmware are not
visible or manageable in SecurePath 3.1A. This means that
SecurePath cannot be used to administer these LUNs, and
that multiple data paths for a no single point of failure
(NSPOF) configuration will result in multiple instances of
the physical device.
StorageWorks by Compaq NAS Exectutor E7000 Release Notes
Release Notes
17

Advertisement

Table of Contents
loading

Table of Contents