Identifying The Sections Of The Rack Rails; Locking Tabs - Supermicro SC826E1-R800LP User Manual

Sc826 chassis series
Table of Contents

Advertisement

SC826 Chassis Manual
5-4
Rack Mounting Instructions
This section provides information on installing the SC826 chassis into a rack unit
with the rails provided. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. You should also refer to the instal-
lation instructions that came with the rack unit you are using.
NOTE: This rail will fit a rack between 26" and 33.5" deep.

Identifying the Sections of the Rack Rails

The chassis package includes two rack rail assemblies in the rack mounting kit.
Each assembly consists of two sections: an inner fixed chassis rail that secures
directly to the server chassis and an outer fixed rack rail that secures directly to
the rack itself.
(Inner Rail is preinstalled
to the chassis)
Figure 5-1. Identifying the Sections of the Rack Rails

Locking Tabs

Both chassis rails have a locking tab. The tabs lock the server into place when
installed and pushed fully into the rack. These tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
Inner Rails
Inner Rail Extensions
5-4
Rail Locking Tabs

Advertisement

Table of Contents
loading

Table of Contents