Yamaha 01V96i Reference Manual page 21

Reference manual
Hide thumbs Also See for 01V96i:
Table of Contents

Advertisement

EQ'ing Input Channels
The 01V96i's Input Channels feature 4-band (LOW,
LOW-MID, HIGH-MID, HIGH) parametric EQ. The
LOW-MID and HIGH-MID bands are a peaking type of EQ.
The LOW and HIGH bands can be set to shelving, peaking,
or HPF and LPF respectively.
1.
Press the [SEL] button of the channel for
which you want to adjust EQ.
2.
Press the DISPLAY ACCEESS [EQ] button, then
press the [F1] button to display the EQ | EQ
Edit page.
1
2
3
The parameters on this page are described below:
1
EQ ON
The ON/OFF button turns the currently-selected Input
Channel's EQ on or off. You can press the [ENTER] but-
ton to turn the EQ on or off as long as the cursor is located
on any parameter other than TYPE.
2
TYPE
Selects the type of EQ. TYPE I is the EQ type used on leg-
acy Yamaha 02R series digital mixing consoles. The
TYPE II algorithm minimizes the interference between
bands.
3
ATT
Determines the amount of pre-EQ signal attenuation in
dB. It is the same Attenuator parameter that appears on
the EQ | ATT In page.
4
CURVE
This area displays the current EQ curve.
5
Meters
These meters indicate the post-EQ signal levels of the
currently-selected Input Channel and its available pair
partner.
4
5
6
Setting the Input Channels from the Display
6
LOW, L-MID, H-MID, HIGH sections
These sections contain the Q, Frequency (F), and Gain
(G) parameters for the four bands. These parameter val-
ues range as follows:
Parameter
LOW
HPF, 10.0
to 0.10
Q
(41 steps),
L.SHELF
Frequency
Gain
–18.0 dB to +18.0 dB (0.1 dB steps)
1. The LOW and HIGH GAIN controls function as filter
on/off controls when Q is set to HPF or LPF respec-
tively.
Tip:
• The LOW-band EQ functions as a high-pass filter when
the Q parameter in the LOW section is set to HPF. It func-
tions as a shelving-type EQ when the Q parameter is set
to L.SHELF.
• The HIGH-band EQ functions as a low-pass filter when
the Q parameter in the HIGH section is set to LPF. It func-
tions as a shelving-type EQ when the Q parameter is set
to H.SHELF.
3.
Move the cursor to the desired parameter,
then rotate the Parameter wheel to change
the value.
Tip:
• The EQ settings for the ST IN Channels L & R are linked
to each other.
• You can also press the buttons in the SELECTED CHAN-
NEL section to select the desired band and use the rotary
controls to directly edit the Q, F, and G parameters (see
page 25).
• You can store the EQ settings in the EQ library, which fea-
tures preset programs that can be used for various appli-
cations (see page 147).
LOW-
HIGH-
HIGH
MID
MID
LPF, 10.0
10.0 to 0.10
to 0.10
(41 steps)
(41 steps),
H.SHELF
21.2 Hz to 20.0 kHz
(120 steps per 1/12 octave)
01V96i—Reference Manual
21
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents