5-18 Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant ML370
Table 5-9
ServerNet I Notice Messages
Messages
Link exception condition on path
n has been resolved.
Re-enabling path n
Successfully recovered from
frozen SAIL
Switching to path n
continued
Description
Indicates that a link exception
condition on a path is resolved
and that link exception detection
and processing is re-enabled for
that path. The path becomes
available for ServerNet I
communications within the next
minute. Link exception reporting
must be enabled (see spam –l
on command) for this message
to be displayed.
Indicates that the SAIL
application-specific integrate
circuit (ASIC) stopped
responding due to an internal
self-check problem (usually
from being held off of the PCI
bus too long). After detecting the
self-check, the ASIC is reset and
processing resumes.
Indicates that the SPAD cannot
communicate over the current
path, so SPAD is attempting to
switch to the other path to
determine if SPAD can
communicate over the path.
User Action
None
None
Check cabling on the path being
switched from. Use the
onall spam –v command to find
the path that is down.