PCIe Training
Error: Expected
Link Width is x,
Actual Link
Width is y.
SATA Portx
device not
found.
SATA port x
device auto-
sensing error.
SATA port x
device
configuration
error.
SATA port x
device error.
The amount of
system memory
has changed.
Time-of-day not
set - please run
SETUP program.
Causes
Faulty or improperly
installed PCIe card in the
specified slot.
There is no device connected
to the specified SATA port.
The drive connected to the
specified SATA port is faulty.
Memory has been added or
removed or a memory
module may be faulty.
Incorrect Time or Date
settings; faulty system
battery.
Corrective Actions
Reseat the PCIe card in the
specified slot number. See
"Troubleshooting Expansion
Cards" on page 112. If the
problem persists, see
"Getting Help" on page 123.
Information only.
Replace the faulty drive.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
"Troubleshooting System
Memory" on page 107.
Check the Time and Date
settings. See "Using the
System Setup Program and
Boot Manager" on page 23. If
the problem persists, replace
the system battery. See
"System Memory" on
page 73.