Table 1-2. System Messages
Message
The following
DIMMs should
in
match
geometry:
x,x,...
The following
DIMMs should
in rank
match
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
in size
match
and geometry:
x,x,...
The following
DIMMs should
in size
match
and rank count:
x,x,...
Thermal sensor
not detected on x
Time-of-day
clock stopped
46
About Your System
(continued)
Causes
Invalid memory
configuration. The specified
memory modules do not
match in size, number
of ranks, or number of
data lanes.
A memory module without a
thermal sensor is installed in
the specified memory slot
Faulty battery or faulty chip. See "Troubleshooting the
Corrective Actions
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 98.
Replace the memory module.
See "Expansion Cards" on
page 103.
System Battery" on page 134.