Dell POWERVAULT NX200 Hardware Owner's Manual page 25

Dell personal computer user manual
Hide thumbs Also See for POWERVAULT NX200:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages
Code
Text
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
E122A CPU # VTT
Regulator
failure.
Reseat CPU.
E122C CPU Power
Fault. Power
cycle AC.
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
E122E On-board
regulator
failed. Call
support.
E1310 Fan ## RPM
exceeding
range.
Check fan.
(continued)
Causes
Specified processor
VCORE voltage regulator
has failed.
Specified processor VTT
voltage regulator has failed.
A power fault was
detected when powering
up the processor.
One of the memory
regulators has failed.
One of the on-board
voltage regulators failed.
RPM of fan is outside of
the intended operating
range.
Corrective Actions
Reseat the processor.
See "Troubleshooting the
Processor" on page 144.
If the problem persists,
see "Getting Help" on
page 157.
Reseat the processor.
See "Troubleshooting the
Processor" on page 144.
If the problem persists,
see "Getting Help" on
page 157.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 157.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 137.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 157.
See "Troubleshooting
System Cooling Problems"
on page 136.
About Your System
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents