Table 1-6. System Messages (continued)
Message
Operating system not found
Please connect USB
keyboard/mouse to USB
ports on the back of the
computer
Plug and play
configuration error
Read fault
Requested sector not found The operating system cannot read
Reset failed
Sector not found
Seek error
Shutdown failure
The amount of system
memory has changed
The file being copied is
too large for the
destination drive.
24
About Your System
Causes
The keyboard and/or mouse is not
properly connected.
An attached device is improperly
configured.
The operating system cannot read
from the diskette or hard drive, the
system could not find a particular
sector on the disk, or the requested
sector is defective.
from the diskette or hard drive, the
system could not find a particular
sector on the disk, or the requested
sector is defective.
The disk reset operation failed.
A faulty diskette drive or hard drive.
A chip on the system board might be
malfunctioning.
Memory has been added or removed,
or a memory module may be faulty.
The file that you are trying to copy is
too large to fit on the disk.
Corrective Actions
See "Troubleshooting a Hard Drive" on
page 91. If the problem persists, see
"Getting Help" on page 107.
See "Troubleshooting a USB Device" on
page 82.
See "Troubleshooting Your System" on
page 79.
See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
See "Troubleshooting a Diskette Drive"
on page 89 or "Troubleshooting a Hard
Drive" on page 91.
Run the system diagnostics. See
"Running the System Diagnostics" on
page 97.
If memory has been added or removed,
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" on page 87.
Try increasing disk space on the
destination drive by deleting
unnecessary files.