Chapter 30 Access Control

Table 102 SNMP IP Traps

OPTION
OBJECT LABEL
ping
pingProbeFailed
pingTestFailed
pingTestCompleted
traceroute
traceRoutePathChange
traceRouteTestFailed
traceRouteTestCompleted

Table 103 SNMP Switch Traps

OPTION
OBJECT LABEL
stp
STPNewRoot
MRSTPNewRoot
MSTPNewRoot
STPTopologyChange
MRSTPTopologyChange
MSTPTopologyChange
254
OBJECT ID
DESCRIPTION
1.3.6.1.2.1.80.0.1
This trap is sent when a single ping probe fails.
1.3.6.1.2.1.80.0.2
This trap is sent when a ping test (consisting of
a series of ping probes) fails.
1.3.6.1.2.1.80.0.3
This trap is sent when a ping test is completed.
1.3.6.1.2.1.81.0.1
This trap is sent when a path to a target
changes.
1.3.6.1.2.1.81.0.2
This trap is sent when a traceroute test fails.
1.3.6.1.2.1.81.0.3
This trap is sent when a traceroute test is
completed.
OBJECT ID
1.3.6.1.2.1.17.0.1
ES-3124:
1.3.6.1.4.1.890.1.5.8.12.36.2.1
ES-3124 PWR:
1.3.6.1.4.1.890.1.5.8.14.36.2.1
ES-3124-4F:
1.3.6.1.4.1.890.1.5.8.26.36.2.1
ES-3124F:
1.3.6.1.4.1.890.1.5.8.31.36.2.1
ES-3124:
1.3.6.1.4.1.890.1.5.8.12.107.70.1
ES-3124 PWR:
1.3.6.1.4.1.890.1.5.8.14.107.70.1
ES-3124-4F:
1.3.6.1.4.1.890.1.5.8.26.107.70.1
ES-3124F:
1.3.6.1.4.1.890.1.5.8.31.107.70.1
1.3.6.1.2.1.17.0.2
ES-3124:
1.3.6.1.4.1.890.1.5.8.12.36.2.2
ES-3124 PWR:
1.3.6.1.4.1.890.1.5.8.14.36.2.2
ES-3124-4F:
1.3.6.1.4.1.890.1.5.8.26.36.2.2
ES-3124F:
1.3.6.1.4.1.890.1.5.8.31.36.2.2
ES-3124:
1.3.6.1.4.1.890.1.5.8.12.107.70.2
ES-3124 PWR:
1.3.6.1.4.1.890.1.5.8.14.107.70.2
ES-3124-4F:
1.3.6.1.4.1.890.1.5.8.26.107.70.2
ES-3124F:
1.3.6.1.4.1.890.1.5.8.31.107.70.2
DESCRIPTION
This trap is sent when the STP
root switch changes.
This trap is sent when the MRSTP
root switch changes.
This trap is sent when the MSTP
root switch changes.
This trap is sent when the STP
topology changes.
This trap is sent when the MRSTP
topology changes.
This trap is sent when the MSTP
root switch changes.