Switches 2 and 3 are not used.
Settings in bold typeface in the table below show the factory default configurations.
1
Baud Rate
Configure the transmission rate of connected devices to the transmission rate of the camera.
Transmission Rate Switch 6 Switch 5
2400
OFF
4800
ON
9600
OFF
19200
ON
When protocol is set to "PELCO", set to 2400.
Protocol
2
Select the protocol for controlling the camera.
Protocol
Switch 4
SSP (SANYO) OFF
PELCO
ON
Terminator
3
If you connect multiple cameras, turn "ON" the terminator setting (switch 1) on the last device, and turn "OFF"
those on all other devices.
If you use the RS485 communication mode, assign a unique address (camera No.) to each camera.
Configure the address by setting the dip switches to "ON" and "OFF".
Configure the switches according to the List of Address Configuration Switches shown below. Circles in the list
indicate "ON".
OFF
OFF
ON
ON
Corresponding Protocol
Automatic switching between Sanyo SSP and high speed SSP
Automatic switching between PELCO-D and PELCO-P
Introduction 14/15