Mounting; Rack Mounting - SMC Networks TigerStack II SMC8848M Installation Manual

Gigabit ethernet switch
Hide thumbs Also See for TigerStack II SMC8848M:
Table of Contents

Advertisement

I
NSTALLING THE

Mounting

A TigerStack II 10/100/1000 unit can be mounted in a standard 19-inch
equipment rack or on a desktop or shelf. Mounting instructions for each
type of site follow.

Rack Mounting

Before rack mounting the switch, pay particular attention to the following
factors:
• Temperature: Since the temperature within a rack assembly may be
higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range (see page C-2).
• Mechanical Loading: Do not place any equipment on top of a
rack-mounted unit.
• Circuit Overloading: Be sure that the supply circuit to the rack assembly
is not overloaded.
• Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than
direct connections to the mains.