Rewiring To 110V - Grizzly G0643 Owner's Manual

21-bit line boring machine
Hide thumbs Also See for G0643:
Table of Contents

Advertisement

rewiring to 110v

Rewiring to 110V
The Model G0643 can be converted for 110V
operation. This conversion job consists of dis-
connecting the machine from the power source,
replacing the electrical box, replacing the ON but-
ton/lamp, and rewiring the motor for 110V opera-
tion.
The necessary electrical box and ON button/
lamp for this procedure is the Model G0643 110V
Conversion Kit (Part No. P0643222), and can be
purchased by calling Grizzly Customer Service at
(800) 523-4777.
All wiring changes must be inspected by a quali-
fied electrician before the boring machine is con-
nected to the power source. If, at any time during
this procedure you need help, call Grizzly Tech
Support at (570) 546-9663.
To rewire the Model G0643 for 110V opera-
tion:
1.
DISCONNECT THE BORING MACHINE
FROM POWER!
2.
Remove the electrical box and replace it with
the one included in the 110V Conversion Kit.
Refer to the Electrical Box Wiring Diagram
on Page 32 for a detailed connection illustra-
tion.
Model G0643 21-Bit Line Boring Machine
3.
Verify that the amperage setting on the ther-
mal overload relay is set at 20 amps (see
Figure 3).
��
����
����
���
���
Figure 3. 110V thermal overload relay set at 10
amps.
4.
Open the control panel cover and remove
the ON button/lamp. Replace it with the one
included in the 110V conversion kit.
5.
Rewire the motor for 110V operation as shown
on the diagram located inside the motor junc-
tion box, and close the control panel cover.
Note: The Motor, Control Panel, and Limit
Switch Wiring Diagram on Page 33 was
current at the time of printing, but always
use the motor wiring diagram provided inside
the motor junction box, as it will reflect any
changes to the motor shipped with your
machine.
����
����
���
-9-