Removing and Installing the SODIMMs
To replace or upgrade the DDR-SDRAM SODIMM, follow these instructions:
Figure 4-4
2
1 SODIMM
Both SODIMMs must be of the same size and type.
Note
Use only memory purchased form Cisco Systems.
Note
Attach an ESD-preventative wrist strap between you and an unpainted router surface.
Step 1
Locate the SODIMMs.
Step 2
Press both spring latches outward to release the SODIMM. See
Step 3
Gently pull the SODIMM free from the SODIMM socket, taking care not to touch the pins that insert
Step 4
into the socket. Place the SODIMM in an anti-static bag.
Forcing the SODIMM into the socket can damage the SODIMM. Use the notches on the SODIMM to
Caution
align the SODIMM in the SODIMM socket before inserting it.
Locate the notches and align the SODIMM with the socket before inserting it.
Step 5
Gently insert the new SODIMM at a 30
Step 6
SODIMM.
Press down on the SODIMM until the spring latches lock the SODIMM in place.
Step 7
Repeat Step 1 through Step 7 if you are also replacing the second SODIMM.
Step 8
For memory specifications and configurations, see
Cisco 7301 Installation and Configuration Guide
4-6
Removing and Replacing the SODIMM
1
2
o
angle, taking care not to damage the pins on the edge of the
Chapter 4
Installing and Removing Field-Replaceable Units
2 SODIMM spring latches
Figure
4-4.
Appendix A, "Specifications."