GE AZ61H12DAB Owner's Manual And Installation Instructions page 16

Heat/cool and heat pump models
Hide thumbs Also See for AZ61H12DAB:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
POWER CONNECTION CHART
Power Cord Connections
230/208 Volt
Power Supply Kits
with Current Leakage
Detection Device
RAK3253
I
RAK3203
RAK3303*
Wall Plug
Configuration
Tandem
I
Perpendicular
LargeTandem
Circuit Protective Device
Heater Wattage
@ 230/208 Volts
15-Amp Time-Delag Fuse or Breaker
20-Amp Time-Delag Fuse or Breaker
30-Amp Time-Delag Fuse or Breaker
2,55/2,09
KW
3,4S/2,82 KW
5.00/4.10
KW
Direct Connections
230/208Volt
Power Supplg Kits
RAK4157
I
RAK4207
RAK4307*
265 Volt
Power Supplg Kits
RAK5157
RAK5207
RAK5307*
Circuit Protective Device
Heater Wattage
@ 230/208 Volts
1S-Amp Time-Delag Fuse or Breaker
20-Amp Time-Delag Fuse or Breaker
30-Amp Time-Delag Fuse or Breaker
2,55 KW/2,09 KW
3,45 KW/2,82 KW
5.00 KW/4.10 KW
Circuit Protective Device
Heater Wattage
@ 265 Volts
I
1S-Amp Time-Delag Fuse or Breaker
20-Amp Time-Delag Fuse or Breaker
30-Amp Time-Delag Fuse or Breaker
*Not approved for use on 7000 BTUH units.
2,55 KW
3,45 KW
5.00 KW
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents