Controls - GE AZ41E09DAB Owner's Manual And Installation Instructions

Heat/cool model; heat pump model
Table of Contents

Advertisement

About the controls on your Zoneline.
GEAppliances.com
in
HiGH
=mmCOOL
LOW
_
FAN
AUTO
_
HEAT
m
!
TEIVlP
FAN
MODE
SLEEP OPERATION
TEMP CONTROL FAN,MODE& SLEEP OPERATION
Controls
Temp Control
Thetemp control is usedto maintain the room
temperature.The compressorwill cycleon
and off to keepthe room at the same level
of comfort.
Press the • pad to raisethe temperature.
Press the • pad to lower the temperature.
NOTE: T he displayshows the set temperature,
not the room temperature.
Sleep
Press to set the air conditionerto run for 8 hours
before it automaticallyreturns to the previous
setting.
When in the cooling mode and the sleeptimer
is set,the set temperature will automatically
increase2°Fafter the second hour then :].°F
each hour overthe next two hours.Also,the
fan speedwill changeto low.When in the
heating mode, the set temperature will
decreasein the same manner.
Tocancel the sleepmode, pressthe MODEpad
or the SLEEP pad a second time.
Fan, Mode and Operation Control
FAN--Sets the fan operationfor HIGH,
LOWor AUTO speed.When set at AUTO,
it automatically switchesbetween LOW
and HIGHas room temperature changes.
MODE--COOL--For c ooling
FAN--Forfan-only operation
HEAT--Forheating
OPERATION--ON/STOP--Turns
the unit
on or off. Powerremains connectedto
the Zoneline. T he Freeze/HeatSentinel
features still function if active.See the
Freezer/Heat S entinel s ection on page 6.
NOTE: T hetemperaturedisplaywill flash
to indicate a possibleunit malfunction.Set
operation control to STOPand then restart
the unit. If the flashing light reappears within
30 minutes, coil for service.
Quick Heat Recovery
Activateseach time the thermostat is switchedfrom
STOPor COOLmode to HEATmode. Electricheaters
are energizeduntilthe thermostat set point
is reached.On heat pump models,the heat pump
operationwill resumeat the next call for heat.
About Vour Heat Pump (6100 Series only)
Heat pumps can save money by removing heat
from the outside air-even when the outside
temperature is below freezing-and releasing
that heat indoors.
To get the best performance from your heat pump,
don't change the room thermostat very often.
Raising the heat setting 2-3 degrees will cause
the Zoneline to use its electric heating elements in
order to reach the new temperature setting quickly.
There isa 3-minute minimum compressor
run time at any setting to prevent short cycling.
The indoor fan motor starts before the compressor
and stops after the compressor cycles off.
When the outdoor temperature is lower than 25°F,
heat is provided by the electric heater in the air
conditioner instead of by the heat pump.
The electric heating elements use much
more electricity than heat pumps and cost
more to operate.
3