Problem
Possible
Causes
What
To Do
The air is not always
The heat pump is not
• This is normal. The heat pump will produce warm air
cool or hot during
producing hot air.
but not as hot as air produced when the higher-cost
operation
electric heat is used.
The air does not feel
warm enough during
heating operation
The unit is not
blowing out air
The electric
heating
feature
does not work
Temperature display
flashes
The Smart Fan Auxiliary
Controls may be set to
continuous fan.
This causes the fan to blow room temperature air
even when the compressor or heater cycles off.
The continuous air movement provides better
overall temperature control in the cool mode.
See Smart Fan - Cooling/Heating
on page 5.
The heat pump alone
produces air that feels
cooler than desired.
Use the Electric Heat Option. This turns off the
heat pump and warms with electric heat only.
NOTE: Use of this option will result in increased energy
consumption.
The Smart Fan Auxiliary
• See Smart Fan - Cooling/Heating on page 5.
Controls may be set to cycle.
The power cord is not
firmly attached.
• Remove the room cabinet and make sure that the
yellow connector on the end of the power cord is
firmly engaged.
The compressor may
have failed.
• Set the operation control to STOPand then restart
the unit. If the flashing light reappears within
30 minutes, call for service.