Auxiliary controls on your Zoneline.
Auxiliary Controls--Aux Set Button
The auxiliary set controls are located behind
the room cabinet, below the control panel.
Removethe room cabinet. See the ToRemove
the Room Cabinet section.
The owner is responsible for ensuring the auxiliary
controls are set to the desired function. There are 9
different modes that can be set using the auxiliary
set button. To change modes, press AUXSET("AU"
appears on the display).Pressthe mode button on
the control pad until the first digit in the display
shows the number corresponding to the mode you
are choosing and the correct HEAT/COOL LEDis lit.
Pressthe up or down arrow (shown in the second
digit of the display) to make the mode setting
selection where applicable. Pressthe At.IXSET
button to confirm the selection.
R
First
Digit
B
Load
Shedding
_
constant
Fan
temperature
Limit
_
_Ac_
Class 2
Mode
_"_
Duet
Mode
AH i2R
Mode
(AZ61
OnHy)
Boost
Heat
(AZ61
Ortly)
GEAppliances.com
Auxiliary Set Button
AccessCover
U
Second
Digit
Press
A / V
_,_
= Cycle//
j_j
-Continue
Lq-off
//
_'_ -On
COOL
HEAT
O; 80F=85F
o: 60F-65F
1: 64F=85F
1: 6OF-7OF
2: 66F=85F
2: 60FW2F
3: 68F=85F
3: 60F-74F
\\\\
4: 70F=85F
4: 60F-76F
5: 72F-85F
5: 60F-78F
6: 74F-85F
6: 60F-80F
,
7: 76F=85F
7: 60F-85F
/
//'
U -o_
P_-on
/
MODE i
I Smart Fan--Cooling/Heating
Thedefault setting for Mode 1 is as follows:
Cooling: Continuous (ON)
Heating: Cycle(OFF)
PressMODE until a i appears in the first digit of the
display for Smart Fan cool mode. The COOLLED
light on the main control will be on. To change to
heat mode, press NODE again. The HEATLEDlight
on the main control will be lit. Pressthe down arrow
to set the indoor fan to cycle on/off when the unit is
heating or cooling "u ." Pressthe up arrow to set
the indoor fan to run continuously" n." This is
shown in the second digit of the display. PressAUX
SETto confirm your selection and exit AUXSET
mode, or press NODE to continue setting other
functions.
*Note: In cyclic cooling mode, the indoor fan will activate occasionally to
verify airtemperature in the room. In cyclic heating mode, the fan will
continue to operate for 90seconds after the heating function has stopped in
order to increase unit efficiency.
--
HIGH
_
COOL
t
--LOW
--FAN
_LJ
--AUTO
--HEAT
Cooling - Cycle*
#h'_
--HIGH
_COOL
--LOW
--FAN
--AUTO
--HEAT
Cooling - Continuous
l
-- HIGH -- COOL
lU
--LOW
--FAN
--AUTO
_HEAT
Heating - Cycle*
Ib"_
--HIGH
--COOL
--LOW
--FAN
--AUTO
_HEAT
Heating - Continuous
[ MODE 2
Load Shedding (Central Desk Control)
Thedefault setting for Hode 2 is OFF.
Thisfeature is active only if the unit isconnected to
a CDCand the CDChas control. PressNODE until a
2 appears in the first digit of the display for Load
Shedding mode. Pressthe down arrow for OFF"u
"or the up arrow for ONI--I ." This is shown in the
second digit of the display.When this mode ison,
only the indoor fan can be turned ONor OFFwith
the unit controls. When this mode isoff, all
operation is disabled except Heat/FreezeSentinel
(Mode3).PressAUXSETto confirm your selection
and exit AUXSETmode, or press NODE to continue
setting other functions.
_7
Eu
E
Load
Load
Shedding
Shedding
OFF