Auxiliary controls on your Zoneline.
I MODE31
[ MODE 4
[ MODE 5
[ MODE 6
Freeze Sentinel/Heat
Sentinel
Inthe default settingfor Mode3,Heat Sentinelisoff, Freeze
Sentinelis on.
Press MODE untila 3 appearsin the first digitof the displayfor
Freeze Sentinelmode.TheCOOL.LED l ightqn the maincontrol.
will be on.Press HQDE again to chanqeto the Heat Sentinel. T he
HEAT LEDlighton the maincontrolw_lbe on.Press the down
arrowfor OFF "u "or the up arrowfor ON"n." Thisis shown
in the second` digitat the display.Press AUXSET to contirmyour
selection and exit AUXSETmode,or pressMODE to continue
settingotherfunctions.
VhenFreeze Sentinelis activated,it automaticallyprovides
eat without userinterface. T his helpsto preventplumbing
damagebyturning the heaterand indoorfan ONat 41% and
OFF at 46%.
When Hea_Sentinelis activated,it automaticallyprovides
coolingwithout userinterface. T his helpsto preventan
excessively hot room by turningthe air conditionerONat 85%
and OFFat 80°F.
NOTE: T hesefunctions are active whenever the unit is
plugged in, even if the unit is in the STOP position.
HIGH
U
--LOW
--
AUTO
Freeze S entinel OFF
3B_
HIGH
--
LOW
--
AUTO
Freeze SentinelON
HIGH
U
--LOW
--
AUTO
HeatSentinel OFF
3b'_
HIGH
--
LOW
--
AUTO
HeatSentinel ON
Constant
ON Fan
Thedefaultsettingfor Mode4 isOFF.
Press MODE until a 4 appearsin thefirst digit ofthe displayto set
thefan to run continuously at high speed, e venifthe unit isin
the STOP position.Press the downarrowfor OFF "u" or the up
arrowfor ON"n." Thisisshownin the seconddigitof the
display.Press AUXSET to confirmyour selectionand exitAUX
SETmode,or pressMODE to continuesettingotherfunctions.
h
Constant
Constant
Fan OFF
Fan ON
Temperature Limiting
Thedefault settinqfor Mode 5 isas follows:
Cool:0 (60%to 8_°F}
Heat:7 (60%to 85°F}
Press MODE until a 5 appearsin thefirst digit ofthe displayfor
TemperatureLimiting cool.mode. T h,e COOL t_ED light on the
maincontrolwill be lit. Tochange.toheatmode,pressMODE
agai.n and the HEAT nED lighton the main controlwill be lit. To
setthe tempeEature limits,pressthe up or downarrow keys. T he
seconddigit atthe displaywill be bel_ween 0 and 7 depending on
the limit youwant to set.Thechart showsthe limitsavailable.
Press AUXSET to confirmyourselectionand exitAUXSET mode,
or pressMODE to continuesettingotherfunctions.
Temperaturelimits--Cool
Temperaturelimits--Heat
0 = 60°Fto 85%
0 = 60% to 65%
1 = 64°Fto 85%
1 = 60% to 70%
2= 66°Fto 85%
2 = 60% to 72%
3 = 68°Fto 85%
3 = 60% to 74%
4= 70°Fto 85%
4 = 60% to 76%
5 = 72°Fto 85%
5 = 60% to 78%
6 = 74°Fto 85%
6 = 60% to 80°F
7 = 76°Fto 85%
7 = 60% to 85%
_COOL
--
FAN
--
HEAT
_COOL
--
FAN
--
HEAT
Remote
Thermostat
- Class 2
Thedefaultsettingfor Mode6 is OFF.
Setting this modeto ONwill allowthe unitto operate.with a Class
2 Remote Contro/Wall T hermostat: P ress NODEuntil a 6 appears
in the first digitotthe displayfor Class2 mode.Press thedown
arrowto turn theoptionOFF"u." Press the up arrowto turn this
optionON" m." Thisis shownin the seconddigitotthe display.
Press AUXSETtoconfirmyour selection and exit AUXSETmode,
or pressMODE to continuesettingotherfunctions.
--COOL
--
FAN
HEAT
--COOL
--
FAN
HEAT
C
Cn
Class 2 OFF
Class 2 ON
HIGH
--COOL
53
--LOW
--FAN
--AUTO
reHEAT
Temperature
Limiting
Heat - Limit 3
_
HIGH
_
COOL
_# _
--
LOW
-- FAN
--AUTO
--HEAT
Temperature LimitingCool- Limit 2