Error Code /Status
Code
Message
923
An error occurred during the
loading of a printer. Please
check to make sure the file
chosen was of the correct
type and/or format.
924
No printer loaded.
941
The height and width values
do not agree with the size of
the target file.
942
Unable to configure
densitometer. Densitometer
configuration file may be
corrupt or lost.
1003
Unable to load default
configuration file:_filename_.
1004
Unable to set values
in new configuration file.
1005
Unable to save configuration
file:_filename_.
1006
Configuration file field:_field_
is invalid.
1007
Unable to remove
directory:_directory_.
1101
Density DMIN/DMAX points
are invalid.
1102
Density data is not
monotonic increasing.
1103
Exceeded maximum number
of allowable data errors.
1104
Asymmetric Density
Groupings are invalid.
1201
Unknown response from
densitometer.
September 2000
Possible Cause/Subsystem
An error occurred during the
loading of a printer.
The operator has not yet opened
a printer.
The specified size does not match
the file size.
The file CalDevDensGen2.cfg is
corrupt or lost.
The default configuration file was
deleted or renamed or moved.
An internal error occurred with the
software.
The system is trying to save a file
but there is not enough disk
space.
The user manually edited a field
in a configuration file and entered
an incorrect value.
User does not have update
authority on the directory.
Density points are invalid.
Density data is invalid.
Density data is invalid.
Density data is invalid.
The application received an
unknown response from the
densitometer during
initialization.
Diagnostics and Troubleshooting
Possible Solution
Check that the file chosen was of
the correct format or type.
Open a printer.
Enter the correct file size.
Restart the application. If problem
continues, call for service.
Restore the file manually or
reinstall the software.
Restart the application.
Remove any unnecessary files to
increase free disk space.
• Manually enter the correct
value.
• Reinstall the application.
Verify that the user has authority
on the directory.
Reread density values on
densitometer or make a new
calibration print.
Reread density values on
densitometer or make a new
calibration print.
Reread density values on
densitometer or make a new
calibration print.
Reread density values on
densitometer or make a new
calibration print.
Verify that the baud rate of the
densitometer matches the
applications configuration.
5-19