Download Print this page

Specifications - Omron ZX-GT Datasheet

Smart laser micrometer
Hide thumbs Also See for ZX-GT:

Advertisement

Setup software PCs
Name
Smart Monitor GT
Calculating Units
Appearance

Specifications

Sensor
Item
Output type
Appearance
Light source
Measuring width
Sensing distance
Minimum sensing object
Linearity
Resolution
Temperature characteristic
Indicators (emitter)
Indicator (receiver)
Laser OFF input/sync input
Laser deterioration alarm output
Power consumption (emitter)
Power supply voltage (emitter)
Dielectric strength
Insulation resistance
Operating ambient illumination
(emitter)
Operating ambient illumination
(receiver)
Ambient temperature
Ambient humidity
Vibration resistance (durability)
Degree of protection
Cable length
Material
Weight (packed state)
Accessories
F.S.: 28 mm measuring range of receiver
*1:
Distance between emitter and receiver: 500 mm, measurement object at 250 mm from receiver. Glass ends of chamfer 0.1 mm or more can be detected in glass edge measurement mode.
(at binary level 70%)
*2:
Linearity is given to be a typical error with respect to an ideal straight line when the distance between the emitter and receiver is 100 mm and light is blocked at a distance of 50 mm from the
receiver. (On the ZX-GT2840@@, the measurement object is measured at a distance of 20 mm from the receiver.)
*3:
The amount of fluctuation (±3σ) in the analog output when the distance between the emitter and receiver is 100 mm and a ZX-GTC@@ is connected
*4:
Change in the light cutoff value on one side when the distance between the emitter and receiver is 100 mm and the light is half-cutoff at a distance of 50 mm from the receiver (On the ZX-
GT2840@@, the measurement object is measured at a distance of 20 mm from the receiver.)
*5:
Standard mode (NORM) used
2
Model
ZX-GSW11
Model
ZX-CAL2
ZX-GT28S11
NPN
Separate type
Visible semiconductor laser diode (wavelength 650 nm, CLASS 1 of EN60825-1/IEC60825-1, CLASS of
FDA(21CFR 1040.10 and 1040.11)
28 mm
0 to 500 mm
(*1)
0.5mm dia.
(*2)
±0.1%F.S.
10 µm (number of process values to average: 16)
(*4)
±0.01%F.S/C
Laser ON indicator (green), laser alarm indicator (red)
Optical axis setting indicator (green)
ON: Short-circuited with 0 V or 1.5 V max.
OFF: Open (leakage current: 0.1 mA max.)
NPN open-collector output
30 VDC 20 mA max.
Residual voltage 1.2 V max.
30 mA max.
24 VDC +10%, -15% ripple (p-p) 10% max.
1,000 VAC, 50/60 Hz for 1 min
20 MΩ (at 500 VDC megger)
3,000 lx (incandescent light)
1,000 lx (incandescent light)
Operating: 0 to +40°C Storage: -15 to +50°C(with no icing or condensation)
Operating and storage: 35 to 85% (with no condensation)
10 to 150 Hz Single-amplitude: 0.75 mm for 80 min each in X, Y and Z directions
IEC60529 IP40
2 m
Case: aluminum die-cast, Lens: glass
Approx. 550 g
Laser warning labels, Instruction Sheet
Receiver-Controller Extension Cable
Cable length
Standard cable
1 m
ZX-XGC1A
2 m
ZX-XGC2A
5 m
ZX-XGC5A
8 m
ZX-XGC8A
20 m
ZX-XGC20A
Up to two extension cables can be connected. However, be sure to limit the total extension
cable length between the receiver and the Controller to 30 meters (including the receiver
cable).
ZX-GT2840S11
PNP
Integrated type
Separate type
40 mm
0 to 500 mm
0.2 mm dia.
0.5 mm dia.
(*3)
ON: Short-circuited with power supply voltage or
power supply voltage -1.5 V max.
OFF: Open (leakage current: 0.1 mA max.)
PNP open-collector output
30 VDC 20 mA max.
Residual voltage 2 V max.
(*5)
Approx. 570 g
Approx. 550 g
Displacement sensors / Width-measuring Sensors
Model
Flexible cable
ZX-XGC1R
ZX-XGC2R
ZX-XGC5R
ZX-XGC8R
ZX-XGC20R
ZX-GT28S41
ZX-GT2840S41
Integrated type
40 mm
(*1)
0.2 mm dia.
Approx. 570 g
Quantity
1 m

Advertisement

loading

This manual is also suitable for:

Zx-gt28s11Zx-gt2840s11Zx-gt28s41Zx-gt2840s41