Re-registering the Model of the Specified Item < MODELSET command >
This command re-registers the model of the specified item. It does not reset filters, etc.
< Command format >
M O D E
L S E T
< Response format >
When processing ends successfully
C R
O K
When processing fails
E R
C R
< Explanation of parameters >
Measurement item No.
Specifies the measurement item No.
Measurement items: 0 to 31
Position correction items: 0 to 1
Attribute
Specifies measurement item or position correction item.
0: Measurement item
1: Position correction item
Default is measurement item.
Acquiring/Changing Passwords < PASSWORD command >
Acquiring the password
This command acquires the currently set password.
< Command format >
P A S S
W O R D
C R
< Response format >
When processing ends successfully
C R
Password
O K
C R
When processing fails
E R
C R
< Explanation of parameters >
Password
A password of any eight alphanumeric characters is returned.
ZFX-C Serial Communication Command Reference
or
C R
M S
Attribute
Measurement
item No.
(max. 2 digits)
or
P W
C R
C R
Attribute
Measurement
item No.
(max. 2 digits)