1-4 Installing the Intelligent Cameras
1-4-2
Installing the mounting fixture
Removal procedure
1-4-3
Adjusting the camera focus
The mounting fixture can be installed on all of the four mounting surfaces.
1. Align the two hooks on one side of
the mounting fixture with the two
grooves on the camera body.
2. Push the other hook down until it
is snapped into place.
Make sure that the mounting fix-
ture is firmly fixed on the camera.
3. Fasten the mounting fixture at the
mounting location with screws.
Tightening torque
M4: 1.2 Nm
1/4"-20 UNC: 2.6 Nm
1. Insert a screwdriver into the gap
(one of the two gaps) between the
mounting fixture and the camera
case, and remove the mounting
fixture.
1. Adjust the distance between the
camera and the measurement tar-
get and fasten the camera.
Refer to the optical chart and set
the camera in a position so that
the area to be checked is within
the detection area (LCD monitor).
"Optical chart" p. 10.
2. Turn the focus adjustment control
to the left and right to adjust the
focus.
Note First turn the focus adjustment control slightly to the left and right, to make
sure that the Focus adjustment control is not at the upper or lower limit posi-
tions. Do not exert unnecessary force to turn the control at the upper or lower
limit positions as this might damage the control.
(For ZFX-SC90_/SC150_, the control stops turning at the nearest position. It
turns free at the farthest position.)
Preparation
Hooks
Mounting
fixture
Grooves on camera
Mounting fixture
Setting distance (L)
Detection range (H)
Focus
adjustment
control