Enclosures
Model CIMR-G7C
20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
Enclosed type
(IEC IP20)
Open chassis type
(IEC IP00)
Model CIMR-G7C
40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Enclosed type
(IEC IP20)
Open chassis type
(IEC IP00)
Commom specifications
Model number
CIMR-G7C
Control method
Torque characteristics
Speed control range
Speed control accuracy
Speed control response
Torque limits
Torque accuracy
Frequency range
Frequency accuracy
(temperature characteristics)
Frequency setting
resolution
Output frequency
resolution
Overload capacity and
maximum current
Frequency setting signal
Accel/decel time
Braking torque
Main control functions
Motor protection
Instantaneous
overcurrent protection
Fuse blown protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power loss ride
through
Cooling fin overheating
Stall prevention
Grounding protection
Charge indicator
Ambient operating
temperature
Ambient operating
humidity
Storage temperature
Application site
Altitude
Vibration
Varispeed G7
Available as standard
Available by removing the upper and lower cover of
enclosed type
Available as standard
Available by removing the upper and lower cover of
enclosed type
Sine wave PWM
Closed loop vector control, open loop vector control 1&2, V/f control, V/f with PG control
Provided (4 quadrant steps can be changed by constant settings.) (Vector control)
0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration time settings)
(Approximately 125% with braking resistor option, braking transistor built into Inverters of 15 kW or less)
Restarting after momentary power loss, speed search, overtorque/undertorque detection, torque limits, 17-speed control
(maximum), 4 acceleration and deceleration times, S-curve acceleration/deceleration, 3-wire control, auto-tuning
(rotational or stationary), dwell function, cooling fan ON/OFF control, slip compensation, torque compensation,
auto-restart after fault, jump frequencies, upper and lower limits for frequency references, DC braking for starting and stopping,
high-slip braking, advanced PID control, energy-saving control, MEMOBUS communications
(RS-485/422, 19.2 kbps maximum), 2 motor parameter sets, fault reset and parameter copy function.
200 Class Inverter: stops when main-circuit DC voltage is above 410 V.
400 Class Inverter: stops when main-circuit DC voltage is above 820 V.
200 Class Inverter: stops when main-circuit DC voltage is below 190 V.
400 Class Inverter: stops when main-circuit DC voltage is below 380 V.
By selecting the momentary power loss method, operation can be continued if power is restored within 2 s.
Stall prevention during acceleration, deceleration and running independently.
Illuminates when the main circuit DC voltage is approx. 10 VDC or more.
- 20 C to + 60 C (short-term temperature during transportation)
Available for option
Available as standard
Specification
150% at 0.3 Hz (open loop vector control 2)
150% at 0rpm (closed vector control)
1:200 (open loop vector control 2)
1:1000 (closed loop vector control)
± 0.2% (open loop vector control)
± 0.02% (closed loop vector control)
(25 C ± 10 C)
10 Hz (open loop vector control 2)
30 Hz (control with PG)
± 5%
0.01 to 400 Hz
Digital references: ± 0.01% (-10 C to +40 C)
Analog references: ± 0.1% (25 C ±10 C)
Digital references: 0.01 Hz
Analog references: 0.025/50 Hz (11 bits plus sign)
0.001 Hz
150% of rated output current for 1 minute
200% of rated output current for 0.5 second
0 to +10 V, -10 to +10 V, 4 to 20 mA, pulse train
Approximately 20%
Protection by electronic thermal overload relay.
Stops at approx. 200% of rated output current.
Stops for fuse blown.
150% of rated current for 1 minute
200% of rated current for 0.5 second
Protection by thermistor.
Protection by electronic circuits.
-10 C to 40 C (enclosed wall-mounted type)
-10 C to 45 C (open chassis type)
95% max. (with no condensation)
Indoor (no corrosive gas, dust, etc.)
1000 m max.
2
10 to 20 Hz, 9.8 m/s
max.; 20 to 50 Hz, 2 m/s
Not
available
Available for option
Available as standard
2
max
Not available
251