Omron VARISPEED G7 Datasheet page 17

Hide thumbs Also See for VARISPEED G7:
Table of Contents

Advertisement

C
Feedback speed control cards
Type
Model
PG-A2 / 3G3FV-PPGA2
PG-B2 / 3G3FV-PPGB2
PG-D2 / 3G3FV-PPGD2
PG-X2 / 3G3FV-PPGX2
D
Communication option cards
Type
Model
SI-N1
SI-P1
SI-S1
SI-J
SI-T
CM090
1.
Please refer to Trajexia, MCH or MP series for host controllers detailed information.
E
Reference option cards
Type
Model
AI-14U / 3G3IV-PAI14U
AI-14B / 3G3IV-PAI14B
DI-08 / 3G3IV-PDI08
DI-16H2 / 3G3IV-PDI16H2
F
PLC option boards
Type
Model
3G3RV-P10ST8-E
3G3RV-P10ST8-DRT-E
Varispeed G7
Description
Function
• Phase A pulse (single pulse) inputs (voltage, complementary, open collector input)
• PG frequency range: Approx. 30 kHz max.
[Power supply output for PG: +12 V, max. current 200 mA]
• Pulse monitor output: +12 V, 20 mA
• Phase A and B pulse inputs (exclusively for complementary input)
• PG frequency range: Approx. 30 kHz max.
[Power supply output for PG: +12 V, Max. current 200 mA]
• Pulse monitor output: Open collector, +24 V, Max. current 30 mA
PG speed controller card
(used for V/f control with PG or
• Phase A pulse (differential pulse) input for V/f control (RS-422 input)
flux vector)
• PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, Max. current 200 mA]
• Pulse monitor output: RS-422
• Phase A, B and Z pulse (differential pulse) inputs (RS-422 input)
• PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, Max. current 200 mA]
• Pulse monitor output: RS-422
Description
Function
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
DeviceNet option card
output frequency, output current, or similar items through DeviceNet communication with the
host controller.
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
PROFIBUS-DP option card
output frequency, output current, or similar items through PROFIBUS-DP communication
with the host controller.
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
CANopen option card
output frequency, output current, or similar items through CANopen communication with the
host controller.
• Used for HVAC control, running or stopping the inverter, setting or referencing parameters,
LONWORKS option card
and monitoring output current, watt-hours, or similar items through LONWORKS communi-
cations with peripheral devices.
• High speed motion bus
• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
MECHATROLINK-II
output frequency, output current, or similar items through MECHATROLINK-II communica-
option board
tion with the host controller.
• Host contoller: Trajexia, MCH and MP series
Ethernet option card
• Modbus TCP/IP ethernet interface unit
Description
Function
• 2 channel high resolution analog input card
• Channel 1: 0 to 10 V (20 K )
• Channel 2: 4 to 20 mA (250
• Resolution 14 bit
Analog input card
• 3 Channel high resolution analog input card
• Signal level: -10 to +10 V (20 K )
•Resolution: 13 bit + sign
• 8 bit digital speed reference input card
Digital reference card
• 16 bit digital speed reference input card
Description
Function
• Full PLC features, wireless installation and seamless access to the inverter parameters and
analogue/digital inputs and outputs.
PLC option
• Embedded Compubus/S fieldbus
• Standard OMRON tools can be used for programming
• Same features as standard models with DeviceNet support.
PLC option with DeviceNet
1
)
4 to 20 mA (250 )
265

Advertisement

Table of Contents
loading

This manual is also suitable for:

Varispeed g7 cimr-g7c

Table of Contents