Receiver Error Codes
Code Group
Error Code
Cascaded Sys-
80
tem Fault
81
82
83
84
85
86
87
88
89
90
91
92
93
95
96
97
98
100
101
Description of Error Code
Configuration Error
Second segment or mute module error
Third segment or mute module error
Fourth segment or mute module error
Mute module error
Configuration error
Second segment or mute module firmware
not compatible with first segment
Third segment or mute module firmware not
compatible with first segment
Fourth segment or mute module firmware
not compatible with first segment
Mute module firmware not compatible with
first segment
Incorrect segment type in position two,
three or four
Segment 2 type does not match segment 1
type
Segment 3 type does not match segment 1
type
Segment 4 type does not match segment 1
type
Error in flex segment or muting module dur-
ing operation
Error in segment 2 during operation
Error in segment 3 during operation
Error in segment 4 during operation
Number of segments in system has been
reduced (changed)
Too many flex nodes or muting modules in
the flex bus
Corrective Action Needed
Please contact your local Omron distributor
or the European Repair Center
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
Check all cable connections to mute mod-
ule. Please contact your local Omron dis-
tributor or the European Repair Center
Please contact your local Omron distributor
or the European Repair Center
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
Confirm that all segments are of the same
type; either all transmitters or receivers
Confirm that segment 2 is the same type
(transmitter or receiver) as segment 1
Confirm that segment 3 is the same type
(transmitter or receiver) as segment 1
Confirm that segment 4 is the same type
(transmitter or receiver) as segment 1
Check all flex connections, segments and
muting modules
Check connections to segment 2. Replace
segment 2 with known good segment 2.
Please contact your local Omron distributor
or the European Repair Center
Check connections to segment 3. Replace
segment 3 with known good segment 3.
Please contact your local Omron distributor
or the European Repair Center
Check connections to segment 4. Replace
segment 4 with known good segment 4.
Please contact your local Omron distributor
or the European Repair Center
Segment count is less than original configu-
ration. Add required segment(s) or program
system for current configuration
Make sure of total of 4 segments with only
one muting module.