System Specification
Response time of MS4800 system
One segment system
Minimum
Maximum
number of
number of
beams
beams
0
16
17
71
72
126
127
180
181
235
236
256
Three segment system
Minimum
Maximum
number of
number of
beams
beams
0
59
60
114
115
168
169
223
224
256
Conformity
AOPD(ESPE)
Safety category
Safety Integrity Level
PFH
Proof test interval
Two segment system
Response
Minimum
Time
number of
beams
14 ms
0
23 ms
66
32 ms
121
41 ms
175
50 ms
230
59 ms
Four segment system
Response
Minimum
Time
number of
beams
23 ms
0
32 ms
54
41 ms
109
50 ms
163
59 ms
218
Type 4 acc. to EN/IEC 61496-1 (2004)
And EN/IEC 61496-2 (2006)
MS4800E system is suitable for safety control systems
up to Category 4 acc. EN954-1 (1996)
MS4800E system is suitable for up to SIL 3 per
IEC 61508
-08
3,5 * 10
Every 2 years (based on max. number of channels in a
4 segment system including muting system).
Section 15-1
Maximum
Response
number of
Time
beams
65
23 ms
120
32 ms
174
41 ms
229
50 ms
256
59 ms
Maximum
Response
number of
Time
beams
53
23 ms
108
32 ms
162
41 ms
217
50 ms
256
59 ms