Operating Mode Selection; Selecting And Programming Fixed Blanking; Selecting And Programming Floating Blanking; Selecting External Device Monitoring (Edm) - Omron MS4800E - MANUAL 2 Operation Manual

Safety light curtain type 4
Hide thumbs Also See for MS4800E - MANUAL 2:
Table of Contents

Advertisement

Operating mode selection

7-1-2
Receiver selector switch settings
Switch A Position
1
Auto Start or Start/
Restart Interlock
2
EDM
3
Scan Code
4
Floating Blanking 1
5
Fixed Blanking
6
Program (Non-safety)
7-2
Operating mode selection
7-3

Selecting and programming Fixed Blanking

7-4

Selecting and programming Floating Blanking

7-5

Selecting External Device Monitoring (EDM)

7-6

Selecting Machine Test Signal (MTS)

20
Function
Switch B Position
1
2
3
4
5
6
1
2
3
4
1
2
3
4
RECEIVER SELECTOR SWITCHES
(Shown in factory default positions)
The operating mode is selected by setting position 1 of switches A and B,
located on the receiver. Any mismatch between the settings of switches A and
B will result in an alarm condition. The available operating modes are auto-
matic start and Start/Restart Interlock.
Refer to section 5-1 Fixed Blanking for details on selecting and programming
Fixed Blanking function.
Floating Blanking is activated by setting position 4 of Switches A and B
located on the receiver.
Note When Floating Blanking is active, the amber LED will illuminate to indicate
that the system is operating in a less sensitive state.
EDM is activated by setting position 2 of Switches A and B located on the
receiver. Any mismatch between the settings of Switches A and B will result in
an alarm condition.
MTS is activated by setting position 2 located on the transmitter end cap.
Function
Auto Start or Start/
Restart Interlock
EDM
Scan Code
Floating Blanking 1
Fixed Blanking
Range (Non-safety)
Operating Mode
Automatic Start
Start/Restart Int
EDM Disabled
EDM Enabled
Scan Code A
Scan Code B
FB1 Disabled
FB1 Enabled
5
6
ON
Fixed Blanking
Disabled
5
6
ON
Enabled
Program
Operating Range
Short Range
Long Range
Section 7-2
Factory Default
Auto Start (OFF)
Disabled (OFF)
Scan Code A (OFF)
Disabled (OFF)
Disabled (OFF)
Program (toggle)
Long Range (ON)
SW A
SW B
1 = Off
1 = Off
1 = On
1 = On
2 = Off
2 = Off
2 = On
2 = On
3 = Off
3 = Off
3 = On
3 = On
4 = Off
4 = Off
4 = On
4 = On
5 = Off
5 = Off
5 = On
5 = On
6 = Toggle
6 = Off
6 = On

Advertisement