Ratings
Supply voltage
Operating voltage range
Power consumption (see note)
Sensor power supply
Insulation resistance
Dielectric withstand voltage
Noise immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Ambient atmosphere
EMC
Approved standards
Weight
Note An Intelligent Signal Processor with DC supply voltage requires approximately 1 A DC as control power
supply current the moment the Intelligent Signal Processor is turned on. Do not forget to take this into con-
sideration when using several Intelligent Signal Processors. When the Intelligent Signal Processor is not in
measuring operation (e.g., the Intelligent Signal Processor has been just turned on or is operating for start-
up compensation time), the display will read "
Appendix A
Specifications
100 to 240 VAC (50/60 Hz); 12 to 24 VDC
85% to 110% of supply voltage
15 VA max. (max. AC load with all indicators lit)
10 W max. (max. DC load with all indicators lit)
80 mA at 12 VDC 10% (Use a power supply of less than 50 VAC or 70 VDC for
input signals.)
20 M min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
2,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
1,500 V on power supply terminals in normal or common mode 1 s, 100 ns for
square-wave noise with 1 ns
Malfunction: 10 to 55 Hz, 0.5-mm for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 0.75-mm for 2 hrs each in X, Y, and Z directions
2
Malfunction: 98 m/s
(10G) for 3 times each in X, Y, and Z directions
2
Destruction: 294 m/s
(30G) for 3 times each in X, Y, and Z directions
Operating: –10 C to 55 C (with no icing)
Storage:
–20 C to 65 C (with no icing)
Operating: 25% to 85% (with no condensation)
Must be free of corrosive gas
Emission Enclosure:
Emission AC Mains:
Immunity ESD:
Immunity-RF-interference:
Immunity Conducted Disturbance: ENV50141:
Immunity Burst:
UL508, CSA22.2; conforms to EN50081-2, EN50082-2, EN61010-1 (IEC1010-1);
conforms to VDE106/part 100 (Finger Protection) when the terminal cover is
mounted.
Approx. 400 g
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-4-2: 4-kV contact discharge (level 2)
8-kV air discharge (level 3)
ENV50140:
10 V/m (amplitude modulated,
80 MHz to 1 GHz) (level 3)
10 V/m (pulse modulated,
900 MHz)
10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4: 2-kV power-line (level 3)
2-kV I/O signal-line (level 4)
" and all outputs will be OFF.