Main Functions - Omron K3MA-F Datasheet

Frequency/rate meter
Hide thumbs Also See for K3MA-F:
Table of Contents

Advertisement

Operation

■ Main Functions

Input Types and Ranges
Frequency range
(setting parameter)
Pulse frequency selection
(p-fre)
Pulse Frequency Selection
Parameter
Setting value
p-fre
3
5k
Note: The default value is "0 to 5 kHz (5k)."
Scaling
When the desired display value is set for a corresponding input, the value will be displayed on a line between two points determining the zero point.
Parameter
Setting value
inp
0 to 99999
dsp
-19999 to 99999
Display value
DISPLAY
Instead of setting by inputting with the
input as scaling input values for teaching. This is useful for making settings while checking the
operation status of the K3MA-F.
6
Frequency/Rate Meter
Function
Selects pulse input signal.
Meaning
0.05 to 30.00 Hz
measurement range
0 to 5 kHz measure-
ment range
Meaning
Input value for dsp
Display value for inp
INPUT
Input value
Teaching with actual values is possible.
Up Key and
Shift Key, current values can be
K3MA-F
Input range (setting parameters)
0.05 to 30.00 Hz
(30)
0 to 5 kHz
(5k)
Parameter
Setting value
dp
%.%%%%
%%.%%%
%%%.%%
%%%%.%
%%%%%
Note:
• The decimal point can be optionally displayed.
• When displaying the decimal point, consider the
• If p-fre is set to 30, the initial setting for the
Setting range
Displayable from − 19999 to 99999
with scaling function.
The position of the decimal point
can be set as desired.
Meaning
Display four digits after decimal point
Display three digits after decimal point
Display two digits after decimal point
Display one digit after decimal point
No decimal point
The initial value will change depending on the
pulse frequency selection.
number of digits to follow the decimal point prior to
setting the scaling display value.
decimal display will be 000.00.

Hide quick links: