I/O Specifications - Omron F250-C50 C55 - SETUP 09-2001 Manual

Vision sensor
Table of Contents

Advertisement

Connecting through the Parallel Interface
Making a Parallel I/O Cable
A parallel I/O cable can be assembled using the following connector and cover
or equivalent components. Keep the cable length less than
CHECK
Double-check the connector wiring for mistakes before turning ON the power
4-1-3

I/O Specifications

Input Specifications
Item
Model
F250-C50 (NPN mode)
Input voltage
12 to 24 VDC
ON current
5 to 15 mA
ON voltage
8.8 V max.
OFF current
0.1 mA max.
OFF voltage
4.5 V min.
ON delay
RESET input: 10 ms max.
Other inputs: 0.5 ms max.
OFF delay
RESET input: 15 ms max.
Other inputs: 0.7 ms max.
Internal circuits
Output Specifications
Item
Model
F250-C50 (NPN mode)
Output voltage
12 to 24 VDC
Load current
45 mA max.
ON residual voltage
2 V max.
OFF leakage current
0.1 mA max.
Internal circuits
Precaution
Do not exceed the maximum load current specified for the F250. The F250 will
be damaged if an output is short-circuited.
36
Component
Connector
Cover
10%
COM IN
+
Input
terminal
10%
Output terminal
COM OUT
Manufacturer
Fujitsu
Fujitsu
Specification
F250-C55 (PNP mode)
Input
terminal
COM IN
Specification
F250-C55 (PNP mode)
Load
+
Section 4-1
Model number
A8I"%E#6V
A8I"%8#7
COM OUT
Load
Output terminal

Advertisement

Table of Contents
loading

This manual is also suitable for:

F250F250-c50F250-c55

Table of Contents