To maintain the F250 in the best condition, perform the following regularly.
Precaution
Place the light cable in the slot in the camera base.
Connect the light cable to the light connector on the back of the Camera.
• Clean the Lens and LED indicators with a lens-cleaning wipe or blow off
dust with an aerosol air sprayer.
• Lightly wipe off dirt with a soft cloth.
Inspection point
Power supply
The voltage measured at the power supply
terminals must be 24 VDC
Ambient tempera-
The operating ambient temperature inside
ture
the cabinet must be between 0 and 50
Ambient humidity
The operating ambient humidity inside the
cabinet must be between 35% and 85%.
Installation
Each component must be firmly secured.
Each cable connector must be correctly
inserted and locked.
The Cameras must be firmly secured.
The camera lens mounts must be firmly
secured.
Indicators
All indicators must light when the power is
turned ON.
Verify that a through-image is displayed.
When using an Intelligent Lighting, verify
that the light level settings are set to their
maximum values.
• Turn OFF the power and take safety precautions before conducting
inspections. Electrical shock can result from attempting safety inspections
with the power turned ON.
• Do not use thinners or benzene to clean the F250. They will damage
F250 components.
Details
+10%
/
.
-15%
C.
Section 5-3
Tools required
Circuit tester
Thermometer
Hygrometer
Phillips screwdriver
---
49