1-conduit Models
Plunger
D4N-1@31
D4N-2@31
D4N-3@31
D4N-4@31
D4N-9@31 (See note 2.)
25
±0.1
Two, 3±0.05 dia.
holes
12 dia.
6-dia. resin
plunger
OP
9
±0.2
2.5
20
± 0.1
± 0.2
± 0.1
47
22
55
2.15±0.05R
mounting holes
± 0.2
22
Conduit cap
31 max.
One-way Roller Arm Lever
(Horizontal)
D4N-1@62
D4N-2@62
D4N-3@62
D4N-4@62
D4N-9@62 (See note 2.)
Operating direction
14.8
12 dia. × 5
±0.2
11
resin roller
13.5
20R
OP
23.3
19.5
±0.2
9
2.5
20
± 0.1
± 0.1
22
47
2.15±0.05R
mounting holes
22
± 0.2
Conduit cap
31 max.
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Refer to page G-231 for details on M12 connectors.
D4N
(31.5)
21.5
±0.2
11
14.2
+0.15
Two, 4
dia. holes
30
0
Depth: 5
(31.5)
21.5
±0.2
11
10.2
±0.2
± 0.2
55
14.2
+0.15
Two, 4
dia. holes
30
0
Depth: 5
Roller Plunger
D4N-1@32
D4N-2@32
D4N-3@32
D4N-4@32
D4N-9@32 (See note 2.)
20.5 × 20.5
9.5 dia. × 5
resin roller
OP
25.2
9
±0.2
2.5
± 0.1
20
47
± 0.2
± 0.1
22
55
2.15±0.05R
mounting holes
± 0.2
22
Conduit cap
31 max.
One-way Roller Arm Lever
(Vertical)
D4N-1@72
D4N-2@72
D4N-3@72
D4N-4@72
D4N-9@72 (See note 2.)
12 dia. × 5
OP
12
resin roller
11
±0.2
R19
±0.2
9
2.15±0.05R
2.5
± 0.1
20
mounting holes
47
± 0.2
22
± 0.1
55
Operating
direction
22
± 0.2
Conduit cap
31 max.
(31.5)
21.5
±0.2
11
14.2
+0.15
Two, 4
dia. holes
30
0
Depth: 5
(31.5)
21.5
±0.2
11
14.7
10.2
±0.2
19.5
14.2
+0.15
Two, 4
dia. holes
30
0
Depth: 5
G-229