Diagnostic Functions

6-7

Diagnostic Functions

6-7-1

Error Log

The following table shows the corresponding settings when using a Program-
ming Console.
Startup conditions
To start without wait-
ing for all Units and
Boards
To start without wait-
ing for all Units (wait
for Boards)
To wait for all Units
and Boards before
starting
Note With CS1G/H-CPU@@(-V1) and CJ1@CPU@@ CPU Units, the CPU Unit will
not start until all Units and Boards have completed startup processing.
Startup Condition
0: If there is one or more of the specific Boards or Units that has not com-
pleted startup processing, the CPU Unit will go on standby in MONITOR or
PROGRAM mode and wait for all Units and Boards.
1: Even if there is one or more of the specific Boards or Units that has not
completed startup processing, the CPU Unit will go ahead and start in MONI-
TOR or PROGRAM mode. The operation for Inner boards, however, also
depends on the following setting.
Inner Board Setting
This setting is used only if the Startup Condition is set to 1 to enable starting
without waiting for specific Units and Boards. This setting is ignored if the
Startup Condition is set to 0.
0: If there is one or more of the specific Boards that has not completed startup
processing, the CPU Unit will go on standby in MONITOR or PROGRAM
mode and wait for all Boards.
1: Even if there is one or more of the specific Boards that has not completed
startup processing, the CPU Unit will go ahead and start in MONITOR or
PROGRAM mode.
This section provides a brief overview of the following diagnostic and debug-
ging functions.
• Error Log
• Output OFF Function
• Failure Alarm Functions (FAL(006) and FALS(007))
• Failure Point Detection (FPD(269)) Function
Each time that an error occurs in a CS/CJ-series PLC, the CPU Unit stores
error information in the Error Log Area. The error information includes the
error code (stored in A400), error contents, and time that the error occurred.
Up to 20 records can be stored in the Error Log.
PLC Setup
Startup Condition
(Programming Console
address 83, bit 15)
1: Enable operation without
waiting.
1: Enable operation without
waiting.
0: Always wait for all Units/
Boards
Section 6-7
Inner Board Setting
(Programming Console
address 84, bit 15)
1: Do not wait for specific
Inner Boards.
0: Wait for all Boards before
starting.
Any
335