Service; Clean Out The Airways; Clean The Filters; Service Interval - Miele PDR 914 Operating And Installation Instructions

Commercial tumble dryers
Table of Contents

Advertisement

Service

Clean out the airways

The tumble dryer's electronic module calculates the degree to which fluff or detergent
residues in the fluff filters and vent ducting are impairing performance. A message to
check the contamination appears. You can decide at what level of fluff this reminder
should be emitted.
If the message appears on the display even though the fluff filter is clean, the vent ducting
is regarded as borderline. Miele recommends improving the vent ducting. Poor vent duct-
ing will result in longer programme running times and greater energy consumption.
This reminder, which you can configure, is displayed:
-
Off
The reminder does not appear. However, if there is a very severe blockage in the ducting,
the programme will be cancelled regardless of this option.
-
Heavy
The reminder only appears when there is a heavy build-up of fluff.
- Factory default: normal
-
Light
The reminder appears when there is only a small build-up of fluff.

Clean the filters

The fluff filter in the air duct area must be cleaned on a regular basis. You can set an hourly
interval for the reminder.
The selected hourly interval depends on how much fluff tends to build up and how often
you wish to clean the filter, e.g. for hygiene purposes.
You can adjust this reminder:
- Time interval of 5–55 hours
- Factory default: after 55 hours
- Off

Service interval

The tumble dryer shows a custom message at a selected interval to prompt you to under-
take specific maintenance tasks.
Three different messages can be created: 1/2/3. Each message is created in the language
and alphabet of the current supervisor language.
Your message is displayed at the end of the programme and can be acknowledged with
The same message appears at the end of the next programme.
Settings
This setting allows you to determine the interval (by hours or date) at which the message
appears.
- Factory default: Off
- By time
You can then select a time interval from 1–9999 hours.
- By date
You can enter a date.
Message text
Clean the filters
Supervisor level
Clean out the airways
.
OK
35