5.3 Adjusting for town gas (5R)

Proceed as described in point "5.2 Regulation for LPG" but select the nozzles and adjust the primary air
flow for town gas, as indicated in the table below and in point "5.5 Regulation of primary air".
Burner
Semirapid
Rapid
Double
Internal
crown
External

5.4 Regulation for natural gas (12T)

To allow the unit to work with this type of gas, perform the same operations described in paragraph "5.2
Regulation for LPG", but choose the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.5 Regulation of primary air". After the regulations have been carried
out, restore the seals with sealing wax or equivalent material.
Burner
Semirapid
Rapid
Double
Internal
crown
External

5.5 Regulation of primary air

Referred to distance "X" in mm.
Burner
Semirapid (2)
Rapid (3)
Double
crown (6)
To identify the burners on your hob, refer to the drawings in point "6.3 Arrangement of burners on hob "
Instructions for the installer
Rated heating capacity (kW)
1.5
2.2
0.8
3.0
Rated heating capacity (kW)
1.5
2.4
1.0
3.4
12T - 2kPa
Internal
External
20Y - 2.8kPa
1.5
2
3.0
3.0
Town gas – (5R) 1kPa
Nozzle diameter 1/100 mm
165
210
140
300
Natural gas - (12T) 2kPa
Nozzle diameter 1/100 mm
92
115
73
140
5R - 1kPa
2
2
6.0
10.0
0.5
1.0
1.0
5.0
19