Instructions for the Installer

7.5 Reassembling the hob skin

Reverse the procedure described in point "7.1 Removing the hob skin".
When replacing the cover plates, check that the seals are fitted correctly.
Fit the pan stands as described in point 9.1Fitting the pan stands.

7.6 Adjusting the minimum setting for natural gas

Reassemble the components on the burner and fit the
knobs onto the tap rods.
Light the burner and turn it to the minimum
Remove the knob again and adjust the regulator
screw inside or beside the tap rod (depending on the
model) until an even minimum flame is obtained.
Put the knob back in place and check the stability of
the burner flame (the flame must not go out when the
knob is turned quickly from the maximum to the
minimum setting).

7.7 Adjusting the minimum setting for liquid gas

Use a pressure regulator and make the connection on the gas cylinder following the
guidelines established by the regulations in force.
Make sure that the feed pressure complies with the values indicated in the table at
point "7.2 Burner and nozzle characteristics table".

7.8 Greasing the gas taps

Over time, the gas taps may become stiff or jam. Clean their insides and change their
lubricating grease. This operation must be carried out by a skilled technician.