10.2 Adjustment for LPG
Unscrew screw C and push air regulator D as far
as it will go.
Using a 7-mm wrench, remove nozzle E and
replace it with the appropriate nozzle, following the
instructions in the tables for the type of gas to be
used. The nozzle tightening torque must be no
more than 3 Nm.
Adjust the air by sliding regulator D until distance
"X" from the table in "10.4 Primary air adjustment"
is reached.
Lock regulator D by tightening screw C.
Burner
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Ultra-rapid (4)
Instructions for the installer
Rated
heating
capacity
(kW)
1.1
1.7
3.0
4.2
LPG – G30/G31 30/37 mbar
Nozzle
Reduced
diameter
capacity
1/100 mm
(W)
48
400
62
500
82
1050
98
1600
Capacity
Capacity
g/h G30
g/h G31
80
79
124
121
218
214
305
300