Heterogeneous Synchronization; Sdr/Sif Synchronization; User Scripts Synchronization And Configuration - Intel NetStructure MPCMM0001 Software Instructions

Chassis management module
Table of Contents

Advertisement

Table 2.
CMM Synchronization (Sheet 2 of 2)
Issues files
/usr/local/cmm/temp/pmssync.ini
/usr/local/cmm/temp/pmsshadowsync.ini
Note: The /.rhosts file is used for synchronization and should NEVER be modified.
3.3

Heterogeneous Synchronization

Beginning in version 5.2 firmware, the CMM can synchronize data between differing CMM
versions. The firmware delineates synchronization from firmware versioning, thus allowing
seamless synchronization between all CMM versions. A form of internal data versioning
maintained by the CMM helps achieve this.
Note: SDR/SIF and user scripts differ slightly in synchronization architecture as described below.
3.3.1

SDR/SIF Synchronization

Sensor Data Records (SDRs) and Sensor Information Files (SIFs) will be synchronized only
between CMMs having the same version for this data item (even if the CMM firmware versions
differ).
3.3.2

User Scripts Synchronization and Configuration

By default, user scripts are synchronized only between CMM's with same firmware versions. User
can control the user scripts synchronization irrespective of CMM version differences by modifying
the value of a configuration flag - "SyncUserScripts" (in the CMM configuration file, cmm.cfg
under /etc). The configuration flag can be modified using the cmmget/cmmset commands. This
flag can be read/set through any of the CMM interfaces (i.e., CLI, SNMP and RPC).
Only when CMM firmware versions differ will the value of this flag determines if user scripts
should be synchronized or not. Between same firmware versions, the user scripts directory will
continue to be synchronized and this flag ignored.
3.3.2.1
Setting User Scripts Sync Configuration Flag
To set the value of the Scripts Synchronization configuration flag, the following CMM command is
used:
cmmget -l cmm -d syncuserscripts -v [equal/upgrade/downgrade/always]
Where:
equal: Synchronizes user scripts only when the CMM versions are same. This is the default value.
MPCMM0001 Chassis Management Module Software Technical Product Specification
Download from Www.Somanuals.com. All Manuals Search And Download.
File(s) or Data
Issues files
Recovery Action and escalation action for all
the monitored processes except monitor
process
Recovery action and escalation action for
monitor process
Redundancy, Synchronization, and Failover
Description
Path
Priority
Ethernet
2
Ethernet
2
Ethernet
2
23

Advertisement

Table of Contents
loading

Table of Contents