Securing The Machine; Electrical Connection - Miele PDR 914 HP Quick Start Manual

Commercial tumble dryers
Hide thumbs Also See for PDR 914 HP:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

Securing the machine

The tumble dryer must be secured to the floor by fitting the tension-
ing strips supplied over the machine feet.
Fittings supplied are for bolting the machine to a concrete floor. For
other types of flooring, please purchase suitable fastening materials
separately.
If the heat-pump unit is tilted up to a maximum of 30° during trans-
portation, it must be left to stand for at least one hour after it has
been installed before the heat-pump dryer can be operated.
If the heat-pump unit was tilted by an angle exceeding 30° or if it was
subjected to strong vibrations, the machine must be left to stand for
24 hours before commissioning.
After transportation and installation, downtime of at least one hour
is required before connecting the tumble dryer to the electricity
supply.
Insufficient downtime before commissioning can damage the heat
pump.

Electrical connection

The electrical connection must be established by a qualified electri-
cian.
The electrical connection may only be made to an electrical system
provided in accordance with all appropriate local and national legisla-
tion, regulations and guidelines. Please also observe the regulations
set out by your insurance provider and energy supplier, accident pre-
vention regulations, as well as recognised codes of practice.
We recommend connecting the tumble dryer to the power supply
via a plug and socket so that it is easier to conduct electrical safety
checks (e.g. during maintenance or repair work).
Reliable and safe operation of this tumble dryer is only ensured if it
has been connected to the mains electricity supply.
The required supply voltage, power rating and fuse rating can be
found on the data plate on the tumble dryer. Ensure that the supply
voltage matches the voltage quoted on the data plate before estab-
lishing the electrical connection to the tumble dryer.
Connection to a supply voltage other than the one quoted on the
data plate can damage the tumble dryer if the voltage is too high.
en - Installation
151

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdr 918 hpPdr 922 hp

Table of Contents