System Specifications - Culligan GoodWater Machine DrinkingWater System Owner's Manual

Drinking water system
Table of Contents

Advertisement

2

System Specifications

System Flow Sequence .................................... Particle Filter, Activated Carbon Filter,
..................................................... Reverse Osmosis Membrane Filter, Storage Tank,
..................................................... Polishing Filter, Dispensing Faucet
Particle Filter ................................................... 5 Micron Spun Polypropylene
Activated Carbon Filter .................................. Solid Carbon Block
Reverse Osmosis Membrane Filter ................. Culligan Aqua-Cleer
System Daily Production Rate to
Pressurized Storage Tank ................................ 12.8 gpd (48.45L) (2 gallon)
Product Production Rate without storage
tank to atmosphere
1
- AC-30 Models ............. 30 gpd (114 L/day)
Ratio of Product to Flush Flow
Soft Water Applications .............. 2:3
Hard Water Applications ............ 1:3 - 1:5
Polishing Filter ................................................ Cullar G Activated Carbon
Dispensing Faucet ........................................... Culligan Aqua-Cleer Faucet Rotary Operation,
Colors ......................................... Polished Chrome or White
Storage Capacity - Standard Tank................. 2 gallons
- Medium Tank ................. 3 gallons
- Large Tank ...................... 9 gallons
Dimensions- Filter Assembly ......................... 7.5"W x 3"D x 16.5"H
- Storage Tank - Std. .................... 9" Diameter x 14"H
- Medium .................................... 11" Diameter x 14"H
- Large ......................................... 15.5" Diameter x 24"H
1
Rating at 50 psi, 77°F, 500 mg/L TDS Influent, Without Storage Tank to atmosphere. This is a factory
specification for membrane production. Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern.
2
May vary with pressure. See Technical Manual for all hard water applications and applications where
TDS exceeds 1000 mg/L (ppm).
3
Except nitrate models.
12.1 gpd (45.8 L) (3 gallon)
11.7 gpd (44.2 L) (9 gallon)
2
3
Stainless Steel and Resin Flow Passages, with
Built-in Siphon Break
Thin Film Composite
®