3.1.1 Types of operation modes

The inverter can be operated in any of "PU operation mode", "external operation mode",
"combined operation mode" and "communication operation mode". Prepare required
instruments and parts according to the operation mode. For the way of changing the
operation mode, refer to page 54.
(1) External operation mode
(factory setting Pr. 79 "operation mode selection" = 0)
Pr. 79 "operation mode selection" is factory-set to 0 and the external operation mode is
selected at power-on.
The inverter is operated using an external start signal and an external frequency setting
signal.
Preparation
• Start signal ....................... Switch, relay, etc.
• Frequency setting signal .. 0 to 5V, 0 to 10V or 4 to 20mA DC
Note: 1. Operation cannot be started by the start signal alone. Both the start signal
and frequency setting signal are required to run the inverter.
(2) PU operation mode (Pr. 79 "operation mode selection" = 1)
The inverter is operated using the optional operation panel or
parameter unit.
Preparation
• Operation unit...................Operation panel (FR-PA02
• Connection cable..............To be prepared for use of the operation panel (FR-PA02
• FR-E5P (option) ...............To be prepared for use of the operation panel away from
signals or multiple speeds from a
potentiometer
or
inverter
PU04)
away from the inverter or for use of the parameter unit (FR-
PU04).
FR-CB2
(option)
the inverter. It is available as a set of operation panel cover
and connection cable junction adaptor.