Speed Display (Pr. 37) - Mitsubishi Electric FR-E560 Series Instruction Manual

Transistorized inverter
Table of Contents

Advertisement

4.2.15 Speed display (Pr. 37)

Pr. 37 "speed display"
The unit of the output frequency display of the operation panel (FR-PA02
(FR-PU04) can be changed from the frequency to the motor speed or machine speed.
Parameter
Number
37
<Setting>
• To display the machine speed, set in Pr. 37 the machine speed for 60Hz operation.
Note: 1. The motor speed is converted into the output frequency and does not match
the actual speed.
2. To change the operation panel monitor (PU main display), refer to Pr. 52.
3. As the operation panel display is 4 digits, "----" is displayed when the
monitored value exceeds "9999".
4. Only the PU monitor display uses the unit set in this parameter. Set the
other speed-related parameters (e.g. Pr. 1) in the frequency unit.
5. Due to the restrictions of the resolution of the set frequency, the displayed
value may be different from the setting for the second decimal place.
Make sure that the running speed setting is correct.
Otherwise, the motor might run at extremely high speed, damaging the
machine.
Factory
Setting
Setting
Range
0, 0.01 to
0
9998
CAUTION
Related parameter
Pr. 52 "operation panel/PU main
display data selection"
Remarks
0: Output
frequency
90
PARAMETERS
) and PU
-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e560-0.75k-naFr-e560-7.5k-na

Table of Contents