Alignment
 Set the transceiver to CH#2 via the "Channel" box
located upper right corner on the "Alignment"
window previously.
 Set the SG output level to 0dBμ EMF with 1.5
kHz deviation ±1kHz.
 To adjustment click the left mouse button on the
"Tight noise SQL" then "Start" button.
 Press "OK" to lock in the new data.
20
Threshold Noise SQL
This parameter is used to Threshold noise SQL.
 Set the transceiver to CH#1 via the "Channel" box
located upper right corner on the "Alignment"
window previously.
 Set the SG output level to -7dBμ EMF with 3 kHz
deviation ±1kHz.
 To adjustment click the left mouse button on the
"Threshold noise SQL" then "Start" button.
 Press "OK" to lock in the new data.