Lincoln Electric IDEALARC SP-255 Service Manual page 87

Hide thumbs Also See for IDEALARC SP-255:
Table of Contents

Advertisement

F-34
CONTROL PC BOARD REMOVAL AND REPLACEMENT
CAUTION
Printed Circuit Boards can be dam-
aged by static electricity. Follow
static handling guidelines detailed in
"PC Board Troubleshooting Proce-
dures" at the beginning of this chap-
ter.
_____________________________
REMOVAL AND REPLACEMENT
PROCEDURE
MATERIALS NEEDED
5/16" Nut Driver
Phillips Head Screwdriver
Static Electricity Grounding Strap
1. Disconnect main input power the
machine.
2. Remove the Case Top and Side
Panels using 5/16" nut driver.
3. Disconnect all wiring harness
plugs and Molex Plugs connected
to the Control Board. See Figure
F.11.
J2
J7
J5
FIGURE F.11 - Wiring Harness and Molex Plug Locations.
TROUBLESHOOTING & REPAIR
SP-255 CONTROL
G2801
J4
J9
J6
IDEALARC
J8
J3
®
SP-255
F-34

Advertisement

Table of Contents
loading

This manual is also suitable for:

1016410165

Table of Contents