F-12
EXPLANATION OF PROMPTING AND ERROR MESSAGES (CONT'D)
ON SCREEN ERROR MESSAGE
DATA ***ERROR***
CHECK SETTINGS
PRESS PROCESS TO
CHECK SETTINGS
MOTOR OVERLOADED
CHECK GUN, DRIVE
XXXX ***ERROR***
CHECK SETTINGS
PRESS PROCESS TO
CHECK SETTINGS
GUN SWITCH BEING
USED FOR TOGGLE
CONNECT FOR
NEG. POLARITY
LOW LINE: CHECK
RECONNECT PANEL
PRESS ANY KEY
TO STOP MESSAGE
TROUBLESHOOTING & REPAIR
An attempt was made to recall a setup from memory that has improper set-
tings due to excessive electrical interference. The SP-255 will recall the
setup and reset the improper data to within machine limits. However, all set-
tings should be checked, properly set if needed, and then resaved to that
memory. This message alternates with the second message until the
Process key is pressed.
Unit shut down even though trigger was closed. There is an excessive cur-
rent draw on the motor. Check for proper size tip, liner and drive rolls, for
any obstructions or bends in the gun cable, and any other factors that would
impede the wire feeding. To resume welding, simply pull the trigger.
Indicates that an error has occurred due to excessive electrical interference.
All of these error types turn off the arc voltage, wire feed speed, and solenoid.
Press the Process key, per second message, and check all settings before
continuing to weld.
This table shows all of the actual lettering which
XXXX
appears in place of XXXX. There is no reason to
IC3I
note which of these occurred unless it occurs fre-
RTI
quently.
SWI
IOT
XIRQ
PWOF
DATA
Reminds the operator that the gun switch is being used to toggle between
memory 4 and memory 5 and, therefore, is not able to control IPM or arc
VOLTS.
Reminds the operator to change the electrode polarity to negative when In-
nershield wire type is selected.
Indicates to operator that the input line voltage is too low to obtain the output
set on the machine. The operator can continue to weld, but the voltage will
be less than what is set on the machine. This message occurs when the line
voltage is less than 75% of nominal line or if the voltage level set on the ma-
chine is not obtainable at that line voltage and load current. The operator
should check if the reconnect panel is wired properly. Lowering the set
VOLTS and/or IPM can eliminate the message. Pressing any key or gun
switch when the operator is not welding will stop the message from being
displayed . Pressing any increment or decrement arrow keys or gun switch
while welding will temporarily stop the message from being displayed (ap-
proximately 1.3 sec.) allowing the operator to view the increase or decrease
in that setting.