NOTE
When the port specified by SIO is
identical with the port used by the
program, the output results might be
inaccurate.
4. Direct connection by emulated serialization on parallel D
2. Direct connection from SO n ( ) to DI n ( )
Parallel port input can be directly connected to serial port output. The relation of the
parallel port and serial port that can be connected is as follows.
[Operation]
1. Select a DI port (from items 5 to 8) in the "SYSTEM > OPTION > SIO" mode.
2. Press the
(EDIT) key.
F 1
SYSTEM>OPTION>SIO
4.Direct SI5() -> DO15()
5.Direct SO2() <- DI2()
6.Direct SO3() <- DI3()
7.Direct SO4() <- DI4()
8.Direct SO5() <- DI5()
SET
NO
3. Press the
(SET) key to enable the connection or the
F 1
cancel the setting.
4. Press the
key to quit setting or select another DI port with the cursor keys to
ESC
continue setting.
Get other manuals https://www.bkmanuals.com
Input device such as valve
DI port
SO port
DI2()
SO2()
DI3()
SO3()
DI4()
SO4()
DI5()
SO5()
NO
NO
NO
NO
NO
3
V8.01
(NO) key to