●Auto-preset
When auto-preset is selected in function selection mode, the set value can be calculated and memorized
from the measured pressure. Repeating the suction and release of the workpiece to be set for several
times will automatically optimize the set value.
(1) Selection of auto-preset OUT1 mode
Press the
button in measurement mode to display [AP1 REdY].
(If setting of OUT1 is not necessary, select [AP1 REdY], and then press
the
and
buttons simultaneously for 1 second or longer.
The display will move to measurement mode).
(2) Preparation of equipment for OUT1
Prepare the equipment for which the pressure of OUT1 is to be set.
(3) Setting of auto-preset for OUT1
Press the
button, [AP1 RUn] will be displayed.
Measurement starts. Operate the device to change the pressure.
(If the
and
longer while [AP1 RUn] is displayed, measurement will be stopped and
measurement mode will return).
(4) Complete setup.
Press the
button to complete auto-preset mode. Then, measurement mode returns.
The settings in auto-preset will be as follows.
•Normal output
P_1 = A - (A - B)/4
H_1 =  (A - B)/2
If setting is not necessary press the
buttons are pressed simultaneously for 1 second or
•Reversed output
n_1 = B + (A - B)/4
H_1 =  (A - B)/2
and
buttons simultaneously for 1 second or longer.
-33-
A = Maximum pressure
B = Minimum pressure