Term
F
F.S.
(full span/full scale)
Fine adjustment mode
Fluid contact part (or wetted
part)
Function selection mode
H
Hysteresis
Hysteresis mode
I
Insulation resistance
K
Key-lock function
M
Manual setting
Maximum applied voltage
Maximum load current
Measurement mode
Min. setting unit
N
Normal output
Operation light
O
Operation mode
Output style
Abbreviation of full span and full scale; difference between the minimum and
maximum rated pressure values. means the maximum fluctuation range of
the pressure switch rated value.
For example, when the rated pressure range is -0.100 to 1.000 [MPa]:
F.S. = 1.000 - (-0.100) = 1.100 [MPa]
(Reference: 1%F.S. = 1.100 x 0.01 = 0.011 [MPa])
Refer to "Display value fine adjustment (function)".
Part of the pressure switch which contacts detected fluid. Pressure sensor,
seal and fitting are included.
A mode in which setting of functions is performed. It is a separate menu from
the pressure setting. If any function settings need to be changed from the
factory default, each setting can be selected with "F". The setting items are:
display colour, operation mode, output type, digital filter, display resolution,
display value fine adjustment, use of auto preset, use of power saving mode,
security code, etc.
Difference between the points at which the pressure switch is turned ON and
OFF.
Refer to the "List of output modes" on page 30.
Insulation resistance of the product. The resistance between the electrical
circuit and the case.
Function that prevents changes to the settings of the Pressure switch
(disables button operation).
Manual pressure setup without using auto preset.
This term is used to distinguish between manual and auto preset pressure
setup.
The maximum voltage that can be connected to the output of an NPN device.
The maximum current that can flow to the output (output line) of the switch
output.
Operating condition in which pressure is being detected and displayed, and
the switch function is working.
Refer to "digit".
One of the switch output types. In hysteresis mode the switch output is turned
ON when pressure equal to or greater than the switch output set value is
detected. In window comparator mode, the switch output is turned ON when
pressure between the switch output set values (P1L to P1H) is detected.
(Refer to the "List of output modes" on page 30.)
A light that turns on when the switch output is ON.
Either hysteresis mode or window comparator mode can be selected.
The operation principle of the switch output. Normal output and reverse output
can be selected.
Please refer to the" List of output modes" on page
-12-
Definition
30
operating conditions.
No.PS※※-OMS0007-D